| 1 | 1. | | Zoning Item | LSK Art, LLC, Conditional Use Permit
Record Number PLN-12556-CUP
Assessor Parcel Numbers (APNs) 317-182-021 and 317-033-007.
Shower’s Mountain/Pilot Ridge area
A Conditional Use Permit for 13,686-square-feet of existing outdoor cannabis cultivation. Water is sourced from a permitted groundwater well and two surface water diversions located in an unnamed Class II watercourse. A total of 115,000 gallons of hard tank storage is proposed. Estimated annual water usage is 125,932 gallons (8.4 gallons/SF/year). Drying and curing occurs on-site, and all processing is currently done outdoors using a trimming machine. Electricity is currently sourced from generators. A Special Permit is also requested for the ongoing use and maintenance of two points of diversion from a Class II watercourse. | | |
Not available
|
Video
|
21-16308
| 1 | 1. | | Zoning Item | Rynearson Parcel Map Subdivision and Special Permit
Record Number PLN-2020-16308
Assessor’s Parcel Number: 510-041-019.
McKinleyville Area
A minor subdivision of an approximately 1.3-acre parcel into two (2) parcels of 0.64 acres and 0.66 acres. The parcel is currently developed with an existing 1,658 square foot single-family residence with a 576 square foot attached garage as well as a 2,052 square foot detached garage and shop building. The home and attached garage will be located on proposed parcel 2 (0.66 acres) while the detached garage/shop will be located on proposed parcel 1 (0.64 acres). Separate water and sewer service is currently provided to both the residence and detached accessory structures by the McKinleyville Community Services District. The property is located within the State Responsibility Area for fire protection (SRA) and an exception to the State Firesafe Regulations has been granted by Cal-FIRE to allow for use of a road (Babler) not meeting the minimum road width and secondary access requirements of the State Firesafe Regulations (1273.01 & 1273.08). | | |
Not available
|
Video
|
21-13204
| 1 | 2. | | Zoning Item | Mark Felix Conditional Use Permit and Special Permit
Record Number PLN-13204-CUP
Assessor’s Parcel Number: 081-021-038.
Myers Flat area
A Conditional Use Permit for 36,990 sf of new outdoor commercial cannabis cultivation, a Special Permit for a commercial processing, manufacturing and distribution facility, and a retail nursery as well as a Special Permit for a reduction in the setback from public lands. | | |
Not available
|
Video
|
21-11672
| 1 | 3. | | Zoning Item | Grouse Valley Farms, Inc, Conditional Use Permit and Special Permit
Record Number PLN-11672-CUP
Assessor Parcel Number (APN) 315-271-006 & 315-073-002.
Hyampom area
A Conditional Use Permit for 22,000 square feet (SF) of existing outdoor and mixed-light cultivation. Outdoor cultivation totals 19,000 SF and the mixed-light cultivation totals 3,000 SF. The site also includes a 960-SF existing appurtenant nursery. Irrigation water is sourced from a permitted groundwater well and an onsite spring diversion. Estimated annual water usage is 145,000 gallons (6.6 gallons/SF/year) with 99,000 gallons of available water storage. Onsite trimming and drying is conducted in an existing building to be replaced with a new 3,000-SF processing and drying building with a rooftop solar system. Power is currently provided by generators. A Special Permit is also required for a setback reduction from Public Lands managed by Six Rivers National Forest to allow for an approximate 300-foot setback from the cultivation area on both the north and east sides of the property. | | |
Not available
|
Video
|
21-11881
| 1 | 4. | | Zoning Item | GLG, LLC, Conditional Use Permit and (3) Special Permits
Record Number PLN-11881-CUP
Assessor’s Parcel Number: 210-071-013
Dinsmore area
A Conditional Use Permit for an existing 26,400-square-foot (SF) cannabis cultivation consisting of 19,080 SF outdoor and 7,320 SF mixed-light cannabis cultivation and onsite processing with 2,640 SF of ancillary nursery activities. Irrigation water is sourced from an onsite groundwater well and a permitted water diversion. Annual water usage of 250,000 gallons (9.5 gallons/SF/year) and proposed water storage is 150,000 gallons in hard sided tanks. Processing would be completed onsite in an existing 1,800-SF metal building. Power is sourced from generators and an existing solar array that provides electricity for water pumps. An existing cabin and proposed 1,200-SF building will serve as employee housing. Special Permits (3) are needed for decommissioning a stream crossing, maintenance of a water diversion, and for one streamside management area (SMA) setback reduction for an existing parking area within the SMA. | | |
Not available
|
Video
|
21-12245
| 1 | 5. | | Zoning Item | Nijushi, LLC, Conditional Use Permit
Record Number PLN-12245-CUP
Assessor’s Parcel Number: 208-271-007.
Bridgeville Area
A Conditional Use Permit for 14,944 square feet (SF) of mixed light cannabis cultivation. Plants are propagated in a 1,488-SF nursery onsite. Irrigation water is sourced from a 450,000-gallon rainwater catchment pond and two (2) points of diversion (PODs). The primary source of electrical power are generators. Note: This project was inadvertently and erroneously noticed for the September 2nd meeting after being separately noticed for and heard on the August 19th Planning Commission meeting, where it was approved. | | |
Not available
|
Video
|
21-12285
| 1 | 6. | | Zoning Item | Humboldt Sunrise Farms, Conditional Use Permit
Record Number PLN-12285-CUP
Assessor’s Parcel Number: 217-411-008.
Blocksburg area
A Conditional Use Permit for continued cultivation of 9,300 square feet of outdoor cannabis cultivation and 1,800 square feet of mixed light cannabis cultivation. Propagation will occur in one (1) 900-square-foot nursery. Water for irrigation will be provided by a 607,700-gallon rainwater catchment pond located on the adjacent parcel (APN 217-411-009) which is under the ownership as the applicant. The applicant anticipates 95,150 gallons of water will be required for irrigation annually. Processing such as drying and curing will occur onsite in a 625-square-foot shed. Further processing such as trimming will occur offsite at a licensed processing facility until the applicant constructs an onsite processing facility. Power for the project will be provided by solar with a backup generator. | | |
Not available
|
Video
|
21-12674
| 1 | 7. | | Zoning Item | Lance Berry, Conditional Use Permit
Record Number PLN-12674-CUP (filed 12-28-2016)
Assessor’s Parcel Number: 208-261-009
Dinsmore area
A Conditional Use Permit for 20,700 square feet (SF) of outdoor cannabis cultivation and 2,700 SF mixed light cultivation for a total cultivation of 23,400 SF and a 2,340 SF Nursery. Cultivation occurs in 6 different locations on the subject parcel, with five (5) locations being outdoor cultivation and one (1) location for mixed light. Irrigation water is sourced from a 388,000-galllon rain catchment pond. Estimated annual water use is 221,000 gallons (9.44 gal/SF). The primary source of electrical power (propagation lights and pump water) is a Honda EU7000 generator. | | |
Not available
|
Video
|
21-15196-15200
| 1 | 8. | | Zoning Item | Platinum King Farms, LLC, Conditional Use Permit and Special Permits
Record Numbers PLN-2018-15196 and PLN-2018-15200
Assessor’s Parcel Number:104-071-004 and 104-071-005
Petrolia area
A Special Permit for 15,700 square feet of existing mixed light and 8,800 square feet of full sun outdoor cannabis cultivation on APN 104-071-004 and a Special Permit for 30,000 square feet of new mixed light cannabis cultivation to occur on APN 104-071-005. Propagation for both parcels will occur on APN 104-071-005 in a of 5,451 square foot nursery. Water for the project will be provided by a proposed 2.5-million-gallon rainwater catchment pond on APN 104-071-004 and by two onsite permitted groundwater wells utilizing solar powered pumps. The applicant estimates 1,012,102 gallons of water will be required for irrigation annually for both projects. Curing, trimming, packaging and storing will occur on APN 104-071-005 in an existing 2,600-square-foot processing facility that is also proposed to be permitted as a commercial processing facility. Power for the project will be provided by PG&E, purch | | |
Not available
|
Video
|
|
|